User's Manual 67. Configuration Parameters Reference
Version 6.8 789 Mediant 500L MSBR
Parameter Description
Web: URL Provisioning Mode
CLI: acs-url-provisioning-mode
[Tr069AcsUrlProvisioningMode]
Defines the method for configuring the URL of the TR-069
ACS.
[0] Manual (default) = URL must be configured
manually on the device. The URL is configured using
the TR069ConnectionRequestUrl parameter.
[1] Automatic = Device uses DHCP Option 43 to obtain
URL address of ACS.
Web: URL
CLI: acl-url
[TR069AcsUrl]
Defines the URL address of the Auto Configuration
Servers (ACS) to which the device connects. For example,
http://10.4.2.1:10301/acs/.
By default, no URL is defined.
Note: This parameter is applicable only if the 'URL
Provisioning Mode' parameter is set to Manual.
Web: Username
CLI: acs-user-name
[TR069AcsUsername]
Defines the login username that the device uses for
authenticated access to the ACS.
The valid value is a string of up to 256 characters. By
default, no username is defined.
Web: Password
CLI: acs-password
[TR069AcsPassword]
Defines the login password that the device uses for
authenticated access to the ACS.
The valid value is a string of up to 256 characters. By
default, no password is defined.
Web: URL
CLI: connection-request-url
[TR069ConnectionRequestUrl
Defines the URL for the ACS connection request. For
example, http://10.31.4.115:82/tr069/.
Web: Username
CLI: connection-request-user-name
[TR069ConnectionRequestUsername]
Defines the connection request username used by the
ACS to connect to the device.
The valid value is a string of up to 256 characters. By
default, no username is defined.
Web: Password
CLI: connection-request-password
[TR069ConnectionRequestPassword]
Defines the connection request password used by the ACS
to connect to the device.
The valid value is a string of up to 256 characters. By
default, no password is defined.
Web: Default Inform Interval
CLI: inform-interval
[TR069PeriodicInformInterval]
Defines the inform interval (in seconds) at which the device
periodically communicates with the ACS. Each time the
device communicates with the ACS, the ACS sends a
response indicating whether or not the ACS has an action
to execute on the device.
The valid value is 0 to 4294967295. The default is 60.
[TR069RetryinimumWaitInterval]
Defines the minimum interval (in seconds) that the device
waits before attempting again to communicate with the
ACS after the previous communication attempt failure.
The valid value is 1 to 65535. The default is 5.
CLI: debug-mode
[TR069DebugMode]
Defines the debug mode level, which is the type of
messages sent to the Syslog server.
The valid value is between 0 and 3, where 0 (default)
means no debug messages are sent and 3 is all message
types are sent.