User's Manual 67. Configuration Parameters Reference
Version 6.8 887 Mediant 500L MSBR
Parameter Description
[3] Events Only = Transparent with Events.
Notes:
This parameter applies only to V.32 and V.32bis modems.
You can also configure this functionality per specific calls,
using IP Profiles (IpProfile_VxxTransportType). For more
information, see ''Configuring IP Profiles'' on page 332.
Web: V.34 Modem Transport Type
EMS: V34 Transport
CLI: V34-modem-transport-type
[V34ModemTransportType]
Determines the V.90/V.34 modem transport type.
[0] Disable = Transparent.
[2] Enable Bypass (default)
[3] Events Only = Transparent with Events.
Note: You can also configure this functionality per specific calls,
using IP Profiles (IpProfile_VxxTransportType). For more
information, see ''Configuring IP Profiles'' on page 332.
EMS: Bell Transport Type
CLI: bell-modem-transport-type
[BellModemTransportType]
Determines the Bell modem transport method.
[0] = Transparent (default)
[2] = Bypass
= Transparent with events
Web/EMS: Fax CNG Mode
CLI: fax_cng_mode
[FaxCNGMode]
Determines the device's handling of fax relay upon detection of
a fax CNG tone or a V.34/Super G3 V8-CM (Call Menu) signal
from originating faxes.
[0] Doesn't send T.38 Re-INVITE = (Default) SIP re-INVITE
is not sent.
[1] Sends on CNG tone = Sends a SIP re-INVITE with T.38
parameters in SDP to the terminating fax upon detection of a
fax CNG tone, if the CNGDetectorMode parameter is set to
1.
[2] Sends on CNG or v8-cn = Sends a SIP re-INVITE with
T.38 parameters in SDP to the terminating fax upon
detection of a fax CNG tone (if the CNGDetectorMode
parameter is set to 1) or upon detection of a V8-CM signal.
Notes:
If this parameter is set to [2] and the CNGDetectorMode
parameter is set to [0], the device sends a re-
detects a V8-CM signal from the originating fax.
This feature is applicable only if the IsFaxUsed parameter is
set to [1] or [3].
The device also sends T.38 re-INVITE if the
CNGDetectorMode parameter is set to [2], regardless of the
FaxCNGMode parameter settings.
Web/EMS: CNG Detector Mode
CLI: coder
[CNGDetectorMode]
Global parameter that enables the detection of the fax calling
tone (CNG) and defines the detection method. You can also
configure this functionality per specific calls, using IP Profiles
(IpProfile_CNGmode). For a detailed description of this
parameter and for configuring this functionality in the IP Profile
table, see ''Configuring IP Profiles'' on page 332.
Note: If this functionality is configured for a specific IP Profile,
the settings of this global parameter is ignored for calls
associated with the IP Profile.
Web: Fax Detect Timeout Since
Connect (msec)
Defines a timeout (in msec) for detecting fax from the Tel side
during an established voice call. The interval starts from when
the voice call is established. If the device detects a fax tone