User's Manual 67. Configuration Parameters Reference
Version 6.8 897 Mediant 500L MSBR
Parameter Description
in the called number. The character 'p' can be used
several times.
For example (for FXS/FXO interfaces), the called number
can be as follows: d1005, dpp699, p9p300. To add the 'd'
and 'p' digits, use the usual number manipulation rules.
For analog interfaces: To use this feature with FXO
interfaces, configure the device to operate in one-stage
dialing mode.
If this parameter is enabled, it is possible to configure the
FXS/FXO interface to wait for dial tone per destination
phone number (before or during dialing of destination
phone number). Therefore, the parameter
IsWaitForDialTone (configurable for the entire device) is
ignored.
For analog interfaces: The FXS interface send SIP 200
OK responses only after the DTMF dialing is complete.
This parameter can also be configured in a Tel Profile.
CLI: replace-nb-sign-w-esc
[ReplaceNumberSignWithEscapeChar]
Determines whether to replace the number sign (#) with the
escape character (%23) in outgoing SIP messages for Tel-
to-IP calls.
[0] Disable (default).
[1] Enable = All number signs #, received in the dialed
DTMF digits are replaced in the outgoing SIP Request-
URI and To headers with the escape sign %23.
Notes:
This parameter is applicable only if the parameter
IsSpecialDigits is set 1.
This parameter is applicable only to analog interfaces.
Web: Special Digit Representation
EMS: Use Digit For Special DTMF
CLI: special-digit-rep
[UseDigitForSpecialDTMF]
Defines the representation for ‘special’ digits (‘*’ and ‘#’) that
are used for out-of-band DTMF signaling (using SIP
INFO/NOTIFY).
[0] Special = (Default) Uses the strings ‘*’ and ‘#’.
[1]
Numeric = Uses the numerical values 10 and 11.