Menu 6 Introduction Parameter x.00
Parameter
description format
Keypad and
display
CT Modbus
RTU
User
programming
CT Soft Menu 0
Advanced parameter
descriptions
68 Commander SK Advanced User Guide
www.controltechniques.com Issue Number: 2
Figure 9-15 Menu 6B logic diagram
MENU 6B
Keypad Control and Clock
1
0
Drive keypad
RUN
STOP
Logic 1
Keypad STOP key enable 6.12
1.49 = 4
Sequencer
Reference
selection
Menu 1A
Reference
selected
indicator
1.49
1
0
Remote LED
Keypad
RUN
STOP
FUNCTION
LED keypad
function key
status
6.11
Logic 1
Clock control
Electricity cost per kWh 6.16
Reset power consumption meter 6.17
Run time clock
6.22 & 6.23
Motor power (kW)
5.03
Power meter
6.24 & 6.25
Running costs
6.26