Menu 9 Introduction Parameter x.00
Parameter
description format
Keypad and
display
CT Modbus
RTU
User
programming
CT Soft Menu 0
Advanced parameter
descriptions
96 Commander SK Advanced User Guide
www.controltechniques.com Issue Number: 2
Figure 9-24 Menu 9B logic diagram
MENU 9B
Motorised Potentiometer
and Binary Sum
9.26
9.27
Rate
9.23
M
0%
100%
-100%
100%
Bi-polar select
9.22
0
1
Reset
9.28
Mode 9.21
0 - Zero at power up
1 - Last value at power up
2 - Zero at power up,only
change when running
3 - Last value at power up,only
change when running
Scaling
9.24
%
Monitor
9.03
21.51
1.01
Destination
9.25
Binary sum
Logic ones (LSB)
9.29
Binary sum
Logic twos
9.30
Binary sum
Logic fours (MSB)
9.31
Offset
9.34
Binary sum
logic output
value
9.32
21.51
1.01
Destination
9.33
9.31 9.299.30 Output
0
0
1
1
1
1
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0 0
1
2
3
4
5
6
7