EasyManuals Logo

D-Link DGS-3100 SERIES Cli Manual

D-Link DGS-3100 SERIES
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #117 background imageLoading...
Page #117 background image
DGS-3100 Series Gigabit Stackable Managed Switch CLI Manual
108
Success.
DGS-3100#
disable asymmetric_vlan
Purpose To disable Asymmetric VLAN on the switch.
Syntax
disable asymmetric_vlan
Description The disable asymmetric_vlan command, along with the enable
asymmetric_vlan command below, is used to disable and enable
Asymmetric VLAN on the Switch.
Parameters None.
Restrictions Only administrator or operator-level users can issue this command.
Example usage:
To disable asymmetric_vlan on the switch:
DGS-3100# disable asymmetric_vlan
Success.
DGS-3100#
show asymmetric_vlan
Purpose To display the Asymmetric VLAN status on the Switch.
Syntax
show asymmetric_vlan
Description The show asymmetric_vlan command displays the Asymmetric
VLAN status on the Switch.
Parameters None.
Restrictions Only administrator or operator-level users can issue this command.
Example usage:
To display Asymmetric VLAN status:
DGS-3100# show asymmetric_vlan
Asymmetric VLAN : Enable
DGS-3100#

Table of Contents

Other manuals for D-Link DGS-3100 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link DGS-3100 SERIES and is the answer not in the manual?

D-Link DGS-3100 SERIES Specifications

General IconGeneral
TypeManaged
LayerLayer 2+
Ports10/100/1000BASE-T
SFP Ports2 or 4 (depends on the model)
Additional SFP PortsNo
VLANsYes
StackingYes, Physical Stacking
QoSYes
Jumbo Frame SupportUp to 9K bytes
ManagementWeb-based
Operating Temperature0°C to 40°C
Humidity10% to 90% non-condensing
Standards ComplianceIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3x, IEEE 802.1D, IEEE 802.1w, IEEE 802.1s, IEEE 802.1Q, IEEE 802.1p
ModelDGS-3100 SERIES
Storage Temperature-40°C to 70°C