EasyManua.ls Logo

D-Link DGS-3100 SERIES - Configuring Daylight Savings Time

D-Link DGS-3100 SERIES
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DGS-3100 Series Gigabit Stackable Managed Switch CLI Manual
50
config snmp system_location
Purpose To enter a description of the location of the Switch.
Syntax
config snmp system_location <sw_location 0-31>
Description The config snmp system_location command enters a description
of the location of the Switch. A maximum of 31 characters can be
used.
Parameters <sw_location 0-31> - A maximum of 31 characters is allowed. A
NULL string is accepted if there is no location desired.
Restrictions Only Administrator or operator-level users can issue this command
Example usage:
To configure the Switch location for ‘HQ 5F’:
DGS3100# config snmp system_location HQ 5F
Success.
DGS3100#
config snmp system_name
Purpose To define the name for the Switch.
Syntax
config snmp system_name <sw_name 0-31>
Description The config snmp system_name command defines the name of the
Switch.
Parameters <sw_name 0-31> - A maximum of 31 characters is allowed. A NULL
string is accepted if no name is desired.
Restrictions Only Administrator or operator-level users can issue this command
Example usage:
To configure the Switch name as ‘DGS-3100 Switch’:
DGS3100# config snmp system_name DGS-3100 Switch
Success.
DGS-3100 Switch#