DGS-3100 Series Gigabit Stackable Managed Switch CLI Manual
147
expressed numerically.
<hh:mm> - The time of day to begin DST in hours and
minutes, expressed using a 24-hour clock.
<week 1-4,last> - The week of the month in which DST
ends, where 1 is the first week, 2 is the second week and
so on, and last is the last week of the month.
<day sun-sat> - The weekday on which DST ends,
expressed using a three character abbreviation (sun, mon,
tue, wed, thu, fri, sat)
<month 1-12> - The month of the year to end DST,
expressed numerically.
<hh:mm> - The time of day to end DST, in hours and
minutes, expressed using a 24-hour clock.
annual - Enables DST seasonal time adjustment on an annual basis.
Annual mode requires that the DST beginning and ending date be
specified concisely. For example, specify to begin DST on April 3
and end DST on October 14. The format for annual mode is as
follows, and in the order listed:
<date 1-31> - The day of the month to begin DST,
expressed numerically.
<month 1-12> - The month of the year to begin DST,
expressed numerically.
<hh:mm> - The time of day to begin DST in hours and
minutes, expressed using a 24-hour clock.
<date 1-31> - The day of the month to end DST, expressed
numerically.
<month 1-12> - The month of the year to end DST,
expressed numerically.
<hh:mm> - The time of day to end DST, in hours and
minutes, expressed using a 24-hour clock.
offset [30 | 60 | 90 | 120] - Indicates the number of minutes to add
during the summertime. The possible offset times are 30, 60, 90,
and 120. The default value is 60.
Restrictions Only Administrator or operator-level users can issue this command.
Example usage:
To configure daylight savings time on the Switch to run from the 2
nd
Tuesday in April at 3 PM until the 2
nd
Wednesday in
October at 3:30 PM and add 30 minutes at the onset of DST:
DGS3100# config dst repeating 2 tue 4 15:00 2 wed 10 15:30 offset 30
Success.
DGS3100#

Table of Contents

Other manuals for D-Link DGS-3100 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link DGS-3100 SERIES and is the answer not in the manual?

D-Link DGS-3100 SERIES Specifications

General IconGeneral
TypeManaged
LayerLayer 2+
Ports10/100/1000BASE-T
SFP Ports2 or 4 (depends on the model)
Additional SFP PortsNo
VLANsYes
StackingYes, Physical Stacking
QoSYes
Jumbo Frame SupportUp to 9K bytes
ManagementWeb-based
Operating Temperature0°C to 40°C
Humidity10% to 90% non-condensing
Standards ComplianceIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3x, IEEE 802.1D, IEEE 802.1w, IEEE 802.1s, IEEE 802.1Q, IEEE 802.1p
ModelDGS-3100 SERIES
Storage Temperature-40°C to 70°C

Related product manuals