DGS-3100 Series Gigabit Stackable Managed Switch CLI Manual
29
each unit.
Syntax
show environment
Description The show environment command displays the side fan status as
well as the temperature for each unit in the stack and the warning
temperature of each unit, which means the maximum allowed
operating temperature of the device.
NA means that the device HW revision does not support temperature
reading
Parameters None.
Restrictions None.
Example usage:
To display the Environment options:
DGS-3100# show environment
Unit Side Fan Temperature Warning
(Celsius) Temperature
---- ------------ ------------------- -----------------
1 OK NA NA
3 OK 32 63
4 OK 34 79
5 OK NA NA
DGS-3100#