EasyManuals Logo
Home>Danfoss>Air Compressor>Turbocor VTT Series

Danfoss Turbocor VTT Series User Manual

Danfoss Turbocor VTT Series
165 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #144 background imageLoading...
Page #144 background image
144 of 165 M-SV-VT-001-EN Rev. A
OEM Module Components
5.1.1 DC-DC Connections
1. HV DC IN J1
2. 250 V DC OUT J2
3. 24 V DC OUT J4
4. Ground M4, M5, J6, and J7
5.1.2 Removal and
Installation
Removal (Revisions A and B):
1. Isolate the VFD power as described in the “Electrical Isolation of the Compressor/VFD” section of
this manual.
2. Open the panel containing the DC-DC. Verify the HV DC input from VFD is below 5 VDC by
checking at VDC+ (J12) and VDC- (J13) test points on DC-DC with a DC voltage meter.
3. Disconnect the HV DC input cable from J1; 24 VDC output cable from J4; and 250 VDC output
cable from J2. Refer to Figures 186 (DC-DC J1 Connection and J12-J13 Test Points) and 2 (DC-DC
J2 and J4 Connections).
Figure 186 - DC-DC J1
Connection and J12 -J13
Test Points
J13 Test Point
J1 Connector
J12 Test Point

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss Turbocor VTT Series and is the answer not in the manual?

Danfoss Turbocor VTT Series Specifications

General IconGeneral
BrandDanfoss
ModelTurbocor VTT Series
CategoryAir Compressor
LanguageEnglish

Related product manuals