22 Accumulative running time
reached
23
Zero-speed running 2 (having output at
stop)
24
Accumulative power-on time
25
Frequency level detection FDT2 output
26
Frequency 1 reached
27
Frequency 2 reached
28
Current 1 reached
29
Current 2 reached
30
Timing reached
31
VI input limit exceeded
32
Load becoming 0
33
Reverse running
34
Zero current state
35
Module temperature reached
36 Software current limit
exceeded
37
Frequency lower limit reached (having
output at stop
38
Fault output
39
Motor overheat warning
40 Current running time reached 41 Fault outputno output at
undervoltage
Function description
0No output
The terminal has no function.
1AC drive running
When the AC drive is running and has output frequency (can be zero), the terminal becomes
ON.
2Fault output (stop))
When the AC drive stops due to a fault, the terminal becomes ON.
3Frequency-level detection FDT1 output: Refer to the descriptions of P2.19 and P2.20.
4Frequency reachedRefer to the descriptions of P2.21.