85
P6.01 PID digital
setting
0.0% ~100.0% 1 50 ○
P6.02 PID feedback
source
0:VI
1:CI
3:VI-CI
4:Pulse setting
5:Communication setting
6:VI+CI
7:MAX(|VI|+|CI|)
8:MIN(|VI|,|CI|)
1 0 ○
P6.03
PID action
direction
0:Forward action
1:Reverse action
1 0 ○
P6.04 PID setting
feedback range
0 ~ 65535 1 1000 ○
P6.05 Proportional gain
KP1
0.0 ~ 100.0 0.1 20.0 ○
P6.06 Integral time TI1 0.01S ~ 10.00S 0.01S 2.00S ○
P6.07 Differential time
TD1
0.000S ~ 10.000S 0.001S 0.000S ○
P6.08 Cut-off frequency
of PID reverse
rotation
0.00 to maximum frequency 0.01 2.00HZ ○
P6.09 PID deviation
limit
0.0% ~ 100.0% 0.1% 0.0% ○
P6.10 PID differential
limit
0.00% ~ 100.00 % 0.01% 0.10% ○
P6.11 PID setting 0.00 ~ 650.00S 0.01S 0.00S ○