Command Instance Parameter Values Equivalent web parameter
x25sw 0 lapb1ppar 7, 8, 9, 10
7=128
8=256
9=512
10=1024
LAPB 1 Default Packet Size
x25sw 0 lapb1wpar 1-7 LAPB 1 Default Window Size
x25sw 0 lapb2ppar 7, 8, 9, 10
7=128
8=256
9=512
10=1024
LAPB 2 Default Packet Size
x25sw 0 lapb2wpar 1-7 LAPB 2 Default Window Size
x25sw 0 ipaddr IP address IP Stream or XOT Remote IP
Address
x25sw 0 buipaddr IP address IP Stream or XOT Backup IP
Address
x25sw 0 ip_port 0-65535 IP Stream Port
x25sw 0 iphdr 0, 1, 2
0=Off
1=On
2=8583 Ascii 4
byte
IP Length Header
x25sw 0 srcipadd Interface number
0-65535
Source IP address interface
x25sw 0 srcipent <blank>, PPP,
ETH
Source IP address interface
x25sw 0 noswfac off, on Don't switch facilities
x25sw 0 nostripfac off, on Don't strip facilities
x25sw 0 l2deactcc 0-65535 L2 Deactivation Clear Cause
x25sw 0 x25ver84 off, on
Off=88
On=84
X25 Version
x25sw 0 accdefp7w2 off, on Interpret no facilities on Call
Accept as P7W2
Interfaces are coded as follows:
Parameter value Interface type
0 None