3GS Technical Manual
Issue 4.5 August 2005
Programming Menus 8-101
Additional Information
Inhibiting
Inhibiting a zone/door prevents openings and closings having an effect on the system. If zones/doors have been inhibited, on
selection of FULL set mode, a message will indicate how many are inhibited.
Selection of this option is logged by the system and an asterisk appears beside the log entry to indicate the zone/door has been
inhibited manually (zone/door may also be inhibited via literal commands). The identity of the user selecting the option is also
logged.
The INHIBIT function can be re-entered any number of times to inhibit more zones/doors – existing inhibited zones/doors will
not be affected.
Note The Inhibit command is available to all users with level II access.
Auto Inhibits
When the system is set using a timed command, it has the facility to inhibit up to 200 zones and override system faults such as
Cable Fault
Battery Fault
Fuse Fault
Line Fault
FTC Fault
Clear Inhibits
To clear inhibits, re-enter Inhibit Mode using the installer code followed by the NO key. You are prompted to select zones/doors.
Once selected the message CLEAR ALL INHIBITS? will appear in the display. Press YES to clear the inhibited zones/doors. Press
NO to inhibit more zones/doors. Inhibits are automatically removed after performing an unset/disarm from FULL SET mode.
Note Zones/doors can only be inhibited when the Inhibit attribute has been set to YES.