3GS Technical Manual
Issue 4.5 August 2005
Programming Menus 8-101
Additional Information
Inhibiting
Inhibiting a zone/door prevents openings and closings having an effect on the system. If zones/doors have been inhibited, on
selection of FULL set mode, a message will indicate how many are inhibited.
Selection of this option is logged by the system and an asterisk appears beside the log entry to indicate the zone/door has been
inhibited manually (zone/door may also be inhibited via literal commands). The identity of the user selecting the option is also
logged.
The INHIBIT function can be re-entered any number of times to inhibit more zones/doors – existing inhibited zones/doors will
not be affected.
Note The Inhibit command is available to all users with level II access.
Auto Inhibits
When the system is set using a timed command, it has the facility to inhibit up to 200 zones and override system faults such as
• Cable Fault
• Battery Fault
• Fuse Fault
• Line Fault
• FTC Fault
Clear Inhibits
To clear inhibits, re-enter Inhibit Mode using the installer code followed by the NO key. You are prompted to select zones/doors.
Once selected the message CLEAR ALL INHIBITS? will appear in the display. Press YES to clear the inhibited zones/doors. Press
NO to inhibit more zones/doors. Inhibits are automatically removed after performing an unset/disarm from FULL SET mode.
Note Zones/doors can only be inhibited when the Inhibit attribute has been set to YES.