DMP 128 FlexPlus • Remote Control and Configuration 133
Command ASCII command
(host to device)
Response
(device to host)
Additional description
Directories
Change/Create
directory
Epath/directory/
CJ}
Dirpath/
directory/]
Back to root directory
E/CJ} Dir/]
Up one directory
E..CJ} Dirpath/
directory/]
View current directory
ECJ} path/directory/]
File Commands
Erase current directory
and contained files
E/EF} Ddl]
Erase current directory
and subdirectories
E//EF} Ddl]
List files from current
directory
EDF} filenamexdate/time
length]
filenamexdate/time
length]
filenamexdate/time
length]
...
space_remaining
bytes
left]]
Responses for EDF}
and
ELF} are in the
same format.
List files from current
directory and below
ELF}
Load file to user flash
memory
E+UFfilesize,
filename}
Upl]
Retrieve file from user
flash memory
EfilenameSF}
{responds with 4 bytes of
file size and unprocessed
data in file}
Backup/Restore Device Configuration
Save device
configuration (to
filesystem)
E1*X3@ XF} Cnfg1*X3@]
Restore device
configuration
E0*X3@ XF} Cnfg 0 * X3@]
KEY: X3@
= Configuration type 0 = IP configuration, 2 = device-specific parameters
PRELIMINARY
PRELIMINARY