EasyManuals Logo

Extron electronics DMP 128 FlexPlus User Manual

Extron electronics DMP 128 FlexPlus
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #142 background imageLoading...
Page #142 background image
DMP 128 FlexPlus • Remote Control and Configuration 133
Command ASCII command
(host to device)
Response
(device to host)
Additional description
Directories
Change/Create
directory
Epath/directory/
CJ}
Dirpath/
directory/]
Back to root directory
E/CJ} Dir/]
Up one directory
E..CJ} Dirpath/
directory/]
View current directory
ECJ} path/directory/]
File Commands
Erase current directory
and contained files
E/EF} Ddl]
Erase current directory
and subdirectories
E//EF} Ddl]
List files from current
directory
EDF} filenamexdate/time
length]
filenamexdate/time
length]
filenamexdate/time
length]
...
space_remaining
bytes
left]]
Responses for EDF}
and
ELF} are in the
same format.
List files from current
directory and below
ELF}
Load file to user flash
memory
E+UFfilesize,
filename}
Upl]
Retrieve file from user
flash memory
EfilenameSF}
{responds with 4 bytes of
file size and unprocessed
data in file}
Backup/Restore Device Configuration
Save device
configuration (to
filesystem)
E1*X3@ XF} Cnfg1*X3@]
Restore device
configuration
E0*X3@ XF} Cnfg 0 * X3@]
KEY: X3@
= Configuration type 0 = IP configuration, 2 = device-specific parameters
PRELIMINARY
PRELIMINARY

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics DMP 128 FlexPlus and is the answer not in the manual?

Extron electronics DMP 128 FlexPlus Specifications

General IconGeneral
BrandExtron electronics
ModelDMP 128 FlexPlus
CategoryComputer Hardware
LanguageEnglish

Related product manuals