2.1 System Messages
This section contains system module messages.
Severity Level 2
Error Message 0xaaaaaaaa
Explanation Start of new execution
Recommended Action The system starts to init.
Severity Level 2
Error Message 0xbbbbbbbb
Explanation The auto-download process is finished and the switch is going to
be rebooted.
Recommended Action After the switch is booted, checking if it is joined to the stack and
the version of the switch is upgraded.
Severity Level 2
Error Message 0xcccccccc
Explanation The event log is cleared.
Recommended Action The event log is cleared. There should be one entry in the event
log.
Severity Level 2
Error Message 0xdddddddd
Explanation Single-bit ECC error is detected.
Recommended Action If it is possible, user is recommended to replace the DDR-RAM
module from the blade switch.
Severity Level 2
Error Message 0x4
Explanation This event is logged while a user try to reload a stack, stack
master and stack members will log this event.
Recommended Action Please check if the stack had ever issued a reload command.
Severity Level 2
Error Message 0x0
Explanation This event is logged while a user try to reload a stack member,
stack member will log this event.
Recommended Action Please check if the stack master had ever issued a reload
command to this stack member.