3.2.14 Link-State
This section contains the Link-State module messages.
Error Message ERROR! Interface is used in other group or function.
Explanation User attempt to use a interface that already used in other
Link-State group or other functions.
Recommended Action Make sure the interface is not used by other group or other
functions.
Error Message ERROR! This interface is not the upstream of this group.
Explanation User attempt to remove a invalid interface from Link-State
upstream.
Recommended Action Make sure the interface is in Link-State upstream.
Error Message ERROR! This interface is not the downstream port of this group.
Explanation User attempt to remove a invalid interface from Link-State
downstream.
Recommended Action Make sure the interface is in Link-State downstream.
Error Message ERROR! Please disable this group first.
Explanation User attempt to modify a enabled Link-State group.
Recommended Action Make sure the Link-State group is disabled before modification.
Error Message This logical interface is a member of downstream!!!
Explanation User attempt to assign a logical interface to the upstream
member of Link-State group but the logical interface has been
assigned to the downstream member of Link-State group.
Recommended Action Remove the logical interface from downstream of the Link-State,
and assign the logical interface to the upstream.
Error Message This logical interface is a member of upstream!!!
Explanation User attempt to assign a logical interface to the downstream
member of Link-State group but the logical interface has been
assigned to the upstream member of Link-State group.
Recommended Action Remove the the logical interface from upstream of the
Link-State, and assign the logical interface to the downstream
member.
# Only port-channel interface with internal ports will be allowed
to be set to downstream member.