2.36 SFlow Messages
Severity Level 6
Error Message sFlowPduReceive: Failed to give msgQueue semaphore
Explanation Failed to give msgQueue semaphore
Recommended Action Semaphore lock
Severity Level 6
Error Message sFlowReceiverFlowSampleAdd: Failed to send out datagram
Explanation Failed to send out datagram.
Recommended Action Socket error
Severity Level 6
Error Message sFlowReceiverFlowSampleAdd: sample length is overshooting
max datagram size
Explanation sample length is overshooting max datagram size
Recommended Action Setting sample length
Severity Level 6
Error Message sFlowReceiverSampleAdd: data_format %u not supported
Explanation data_format not supported
Recommended Action Only support : SFLOW_FLOW_SAMPLE,
SFLOW_COUNTERS_SAMPLE
Severity Level 6
Error Message sFlowReceiverFlowSampleWrite: flow record type 1 not
supported
Explanation flow record type not supported
Recommended Action Packet headers are sampled
Severity Level 6
Error Message sFlowReceiverSampleDatagramHeaderWrite: IPv4 agent
address get failed
Explanation IPv4 agent address get failed
Recommended Action Setting IPv4 address
Severity Level 6
Error Message sFlowReceiverSampleDatagramHeaderWrite: IPv6 agent
address get failed
Explanation IPv6 agent address get failed
Recommended Action Setting IPv6 address
Severity Level 6
Error Message sFlowRcvrAddressSet: Failed to give msgQueue semaphore
Explanation Failed to give msgQueue semaphore
Recommended Action Semaphore lock