14.5.4 Replacing the iRMC microSD card
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools: A pair of side-cutting pliers
Preliminary steps
"Locating the defective server" on page 45
.
"Shutting down the server" on page 47.
"Disconnecting the power cord" on page 48.
"Getting access to the component" on page 50.
Remove the system fan module, see "Removing the system fan module" on
page 82.
Replacing the iRMC microSD card
Remove the defective iRMC microSD card, see "Removing the iRMC
microSD card" on page 430.
CAUTION
(not valid for Europe, Middle East, India and Africa)
The iRMC microSD card contains customer information.
After removing the iRMC microSD card, hand the card over to
the customer.
If the customer requests disposal of the defective microSD card,
proceed as follows: Using a pair of side-cutting pliers, cut the
microSD card in half.
Install the new iRMC microSD card, see "Installing the iRMC microSD card"
on page 428.
System board and components