Chapter 4 Element Management System (EMS) Element Properties Configuration
© 2011 Harmonic Inc. 120 ProView 7000 v.2.4, Rev. A
High Definition (HD) Digital Output parameters:
■ Video Format – selects the video format.
Options: 720p@50, 720p@59, 720p@60, 1080i@50, 1080i@59, 1080i@60.
■ Aspect ratio Conversion – selects the aspect ratio conversion for the output stream. To be
performed if the incoming stream aspect ratio is not the same as the configured output
aspect ratio.
Options:
❑ Pillarbox (Side-bars)
❑ Full Screen
❑ Letterbox
❑ Center-cut
■ CV Mon Output (SD) – sets the parameters for the SD analog (CV) monitoring output,
consisting of SD video format, SD aspect ratio and aspect ratio conversion.
Advanced video processing parameters:
■ Blanking – selects the response for blanking mode (underflow). Options: Black, Last Field,
Last Frame.
■ Buffer Management – Options:
❑ Normal
❑ Low Delay – Select this option to use Low Delay mode.
❑ Additional Image Processing
PCR Parameters Tab
The PCR parameters tab provides the EMS user the following information and set-up
capabilities:
■ Clock Source – You can select one of the following clock sources:
❑ Original PCR
❑ Decoder Clock
❑ Genlock
1
– Use this menu to sync with the incoming signal. The Genlock menu enables
two radio buttons:
•Analog – Analog genlocking supports PAL B/G and NTSC. The main output must be
configured to PAL B/G or NTSC. When you use an analog clock source you can
configure the following:
· Horizontal Delay – The range is 0 – 1728 in 37 ns or 27 MHz ticks. The default is 0.
· Vertical Delay – The range is -7 – 6. The default is 0.
· SCH Phase Delay – The range is 0° – 360°. The default is 0.
• Digital – Digital genlocking supports PAL B/G, NTSC, 720P (50, 59, 60 Hz) and 1080i
(50, 59, 60 Hz). The main output must be configured to PAL B/G, NTSC, 720P (50, 59,
60 Hz) or 1080i (50, 59, 60 Hz).
You must select either Analog or Digital. The default is Digital.
1. Only available with certain hardware configurations, see Appendix C on page 185.