Chapter 5 Front Panel Interface Front Panel Root Menu
© 2011 Harmonic Inc. 168 ProView 7000 v.2.4, Rev. A
❑ Admin Status – Use this menu to view or set the Admin Status to one of the following:
• Up – Enable
• Down – Disable
If Admin Status is set to Up and no link is detected, a no link alarm is raised. The default
is Down.
❑ Auto Negotiation – Use this menu to view the Auto Negotiation status or set it to one of
the following:
•On
•Off
The default is On.
❑ PHY Speed – Use this menu to view the PHY speed. When Auto Negotiation is off you can
change PHY Speed to one of the following:
• 100
• 1000
The default is 1000.
❑ Duplex Mode – Only Full Duplex Mode is supported.
■ Socket Configuration – Socket Out – Use this menu to configure the 4 socket outs, namely:
•Socket 1
•Socket 2
•Socket 3
•Socket 4
All 4 sockets are associated to both IP ports. The sockets support IGMP v1, v2 and v3 and
automatically detect the version.
In each socket menu you can configure the following (mode out):
• Destination IP Address – Only multicast IP addresses are supported. The default
address is 255.1.1.X (X is the socket number).
• Destination UDP Port – The range is 0 – 65535. The default is 1000.
• Source UDP Port – The range is 0 – 65535. The default is 1024.
• Socket Status – Up or Down
In each socket menu you can configure the following (mode in):
• Socket Admin Status – The options are:
·Up
·Down
• Traffic Parameters
· IP Address Type – The options are: Unicast, Multicast. The default is Multicast.
· IP Address – (Only displays if IP Address Type is Multicast.) You can configure the
same Destination IP Address and UDP Port for several sockets if you define the
Source Specific Multicast and the Source IP Addresses are different. When the IP
Address Type is Unicast, the ProView 7000 uses the active port IP address. When
the IP Address Type is Multicast, you must enter the multicast IP address. The
default is 238.1.1.X (X is the socket number).