200
Installation
Outdoor unit: AHZ-080HCDS1 Indoor unit: /
Outdoor side heat exchanger of air conditioner/heat pump: air
Indoor side heat exchanger of air conditioner/heat pump: water
Type: compressor driven vapour compression
Driver of compressor: electric motor
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season
Item Symbol Value Unit Item Symbol Value unit
Heating
Parameters shall be declared for: Low temperature application
Indoor heat exchanger: Variable outlet
Rated heating capacity P
rated,h
6.52 kW
Seasonal space heating
197 %
Declared heating capacity for part load at indoor temperature
20 °C and outdoor temperature Tj
indoor temperature 20 °C and outdoor temperature Tj
Tj = – 7°C Pdh 5.74 kW Tj = – 7°C COPd 3.09 —
Tj = 2°C Pdh 3.47 kW Tj = 2°C COPd 4.76 —
Tj = 7°C Pdh 2.44 kW Tj = 7°C COPd 6.65 —
Tj = 12°C Pdh 1.48 kW Tj = 12°C COPd 9.58 —
Tj = bivalent temperature Pdh 5.74 kW Tj = bivalent temperature COPd 3.09 —
Tj = operating limit Pdh 6.14 kW Tj = operating limit COPd 2.84 —
Bivalent temperature Operating limit temperature
heating/Average Tbiv -7 °C heating/Average Tol -10 °C
heating/Warmer Tbiv — °C heating/Warmer To l — °C
heating/Colder Tbiv — °C heating/Colder To l — °C
Cd 0.9
Power consumption in modes other than ‘active mode’
P
OFF
0.010 kW Standby mode PSB 0.010 kW
mode(heating)
P
TO
0.011 kW Crankcase heater mode PCK 0.000 kW
Supplementary heater
Supplementary capacity P
SUP
0.349 kW Type of energy input Electric
Other items
Capacity control Variable 2700 m
3
/h
Reference annual heating
demand
Q
H
13406 kWh
Sound power level ,
outdoor measured
LWA 64 dB(A)
Annual energy consumption Q
HE
2680 kWh Global warming potential GWP 675 kgCO
2
eq.
Contact details
Qingdao Hisense Hitachi Air-conditioning Systems Co., Ltd
No. 218, Qianwangang Road, Economic and Technological Development Zone, Qingdao, China