10
General data
2.2.2 ERP data - Hi-Therma Integra
Model
44(2.0 HP) 60(2.5 HP) 80(3.0 HP)
Outdoor unit AHW-044HCDS1 AHW-060HCDS1 AHW-080HCDS1
Indoor unit AHS-044HCDSAA-23 AHS-060HCDSAA-23 AHS-080HCDSAA-23
Water outlet temperature 35°C 55°C 35°C 55°C 35°C 55°C
Product description
Air to water heat pump - Yes
Indication if the heater is equipped
with a supplementary heater
- No
Parameters shall be declared for - Low temperature /Medium temperature application
Parameters shall be declared for the average heating season
Outdoor side heat exchanger of air
conditioner/heat pump
- Air
Indoor side heat exchanger of air
conditioner/heat pump
- Water
Type - Compressor driven vapour compression
Driver of compressor - Electric motor
Capacity Control Variable
Indoor heat exchanger Variable outlet
Rated heating capacity (Prated,h) kW 4.44 3.87 6.10 5.37 6.50 5.90
Seasonal space heating energy e󰀩ciency (ηs,h) % 197 126 194 130 194 134
Seasonal energy e󰀩ciency ratio heating mode(SCOP) - 5.00 3.23 4.93 3.33 4.92 3.42
Type of energy used - Electricity
Declared heating capacity and coe󰀩cient of performance for part load at indoor temperature 20°C and outdoor temperature Tj
Outdoor temperature (Tj) = -7°C
Pdh kW 3.9 3.4 5.4 4.7 5.8 5.2
COPd - 3.29 1.97 3.13 2.04 3.14 1.85
Outdoor temperature (Tj) = +2°C
Pdh kW 2.4 2.1 3.3 3.0 3.5 3.2
COPd - 4.80 3.22 4.67 3.21 4.84 3.40
Outdoor temperature (Tj) = +7°C
Pdh kW 1.7 1.4 2.0 2.0 2.3 2.1
COPd - 6.44 3.97 6.63 4.34 5.98 4.50
Outdoor temperature (Tj) = +12°C
Pdh kW 2.2 2.0 2.2 2.0 2.0 2.1
COPd - 9.92 7.24 9.92 7.24 9.67 7.71
Outdoor temperature (Tj) = Bivalent
temperature (Tbiv )
Pdh kW 3.9 3.4 5.4 4.7 5.8 5.2
COPd - 3.29 1.97 3.13 2.04 3.14 1.85
Outdoor temperature (Tj) = Limit
operation temperature (TOL)
Pdh kW 4.3 3.5 5.3 4.5 6.2 5.7
COPd - 2.62 1.68 2.66 1.75 2.66 1.54
Bivalent temperature (Tbiv) heating/Average °C -7 -7 -7 -7 -7 -7
Limit operation temperature (TOL) heating/Average °C -10 -10 -10 -10 -10 -10
Degradation coe󰀩cient (Cdh) - 0.9 0.9 0.9 0.9 0.9 0.9
Supplementary capacity (PSUP) kW 0.102 0.303 0.729 0.805 0.343 0.179
Annual energy consumption (QHE) kW·h 1824 2457 2539 3312 2732 3536
Model 44 (2.0 HP) 60 (2.5 HP) 80(3.0 HP)
Outdoor unit AHW-044HCDS1 AHW-060HCDS1 AHW-080HCDS1
Indoor unit AHS-044HCDSAA-23 AHS-060HCDSAA-23 AHS-080HCDSAA-23
Declared prole - XL XL XL
Average climate conditions
Water heating energy e󰀩ciency (ηwh) % 135 135 135
Water heating energy class - A+ A+ A+
Daily energy consumption kW·h 5.74 5.74 5.77
Annual energy consumption kW·h 1230 1230 1235
For space heating
For Domestic Hot Water heating