General data
2.3 Cooling mode application (EN 14825)
2.3.1 Cooling data- Hi-Therma Split
Model
44(2.0 HP) 60(2.5 HP) 80(3.0 HP)
Outdoor unit AHW-044HCDS1 AHW-060HCDS1 AHW-080HCDS1
Indoor unit AHM-044HCDSAA AHM-060HCDSAA AHM-080HCDSAA
Water outlet temperature 7°C 18°C 7°C 18°C 7°C 18°C
Product description
Outdoor side heat exchanger of air
conditioner/heat pump
Air
Indoor side heat exchanger of air
conditioner/heat pump
Water
Type Compressor driven vapour compression
Driver of compressor Electric motor
Capacity Control Variable
Indoor heat exchanger Variable Fixed Variable Fixed Variable Fixed
Rated Cooling Capacity (PRATED,C) kW 4.40 5.60 5.0 6.00 6.0 7.0
Seasonal space cooling energy e󰀩ciency (ηS,C) % 227 352 231 346 226 339
Seasonal energy e󰀩ciency ratio cooling mode (SEER) - 5.75 8.87 5.85 8.73 5.73 8.54
Declared cooling capacity and coe󰀩cient of performance for part load at indoor temperature 27(19) °C and outdoor temperature Tj
Outdoor temperature (Tj) = 35°C
Pdc kW 4.4 5.6 5.0 6.0 6.0 7.0
EERd - 3.90 5.60 3.70 5.60 3.60 5.10
Outdoor temperature (Tj) = 30°C
Pdc kW 3.3 4.2 3.7 4.4 4.4 5.1
EERd - 4.98 7.36 5.00 7.01 5.10 6.81
Outdoor temperature (Tj) = 25°C
Pdc kW 2.2 2.6 2.5 2.9 2.8 3.2
EERd - 6.36 10.81 6.59 10.51 6.56 8.87
Outdoor temperature (Tj) = 20°C
Pdc kW 1.2 1.4 1.2 1.4 2.6 1.58
EERd - 8.28 12.27 8.28 12.27 7.93 9.93
Degradation coe󰀩cient (Cdc) - 0.9 0.9 0.9 0.9 0.9 0.9
2.3.2 Cooling data- Hi-Therma Integra
Model
44(2.0 HP) 60(2.5 HP) 80(3.0 HP)
Outdoor unit AHW-044HCDS1 AHW-060HCDS1 AHW-080HCDS1
Indoor unit AHS-044HCDSAA-23 AHS-060HCDSAA-23 AHS-080HCDSAA-23
Water outlet temperature 7°C 18°C 7°C 18°C 7°C 18°C
Product description
Outdoor side heat exchanger of air
conditioner/heat pump
Air
Indoor side heat exchanger of air
conditioner/heat pump
Water
Type Compressor driven vapour compression
Driver of compressor Electric motor
Capacity Control Variable
Indoor heat exchanger Variable Fixed Variable Fixed Variable Fixed
Rated Cooling Capacity (PRATED,C) kW 4.40 5.60 5.0 6.0 6.0 7.0
Seasonal space cooling energy e󰀩ciency (ηS,C) % 227 352 231 346 226 339
Seasonal energy e󰀩ciency ratio cooling mode (SEER) - 5.75 8.87 5.85 8.73 5.73 8.54
Declared cooling capacity and coe󰀩cient of performance for part load at indoor temperature 27(19) °C and outdoor temperature Tj
Outdoor temperature (Tj) = 35°C
Pdc kW 4.4 5.6 5.0 6.0 6.0 7.0
EERd - 3.90 5.60 3.70 5.60 3.60 5.10
Outdoor temperature (Tj) = 30°C
Pdc kW 3.3 4.2 3.7 4.4 4.4 5.1
EERd - 4.98 7.36 5.00 7.01 5.10 6.81
Outdoor temperature (Tj) = 25°C
Pdc kW 2.2 2.6 2.5 2.9 2.8 3.2
EERd - 6.36 10.81 6.59 10.51 6.56 8.87
Outdoor temperature (Tj) = 20°C
Pdc kW 1.2 1.4 1.2 1.4 2.6 1.58
EERd - 8.28 12.27 8.28 12.27 7.93 9.93
Degradation coe󰀩cient (Cdc) - 0.9 0.9 0.9 0.9 0.9 0.9