11
General data
2.2.3 ERP data - Hi-Therma Monobloc
Model
44(2.0 HP) 80(3.0 HP)
Outdoor unit AHZ-044HCDS1 AHZ-080HCDS1
Water outlet temperature 35°C 55°C 35°C 55°C
Product description
Air to water heat pump - Yes
Indication if the heater is equipped
with a supplementary heater
- No
Parameters shall be declared for - Low temperature /Medium temperature application
Parameters shall be declared for the average heating season
Outdoor side heat exchanger of
air conditioner/heat pump
- Air
Indoor side heat exchanger of air
conditioner/heat pump
- Water
Type - Compressor driven vapour compression
Driver of compressor - Electric motor
Capacity Control Variable
Indoor heat exchanger Variable outlet
Rated heating capacity (Prated,h) kW 4.61 4.09 6.52 6.07
Seasonal space heating energy eciency (ηs,h) % 204 136 197 137
Seasonal energy eciency ratio heating mode(SCOP) - 5.17 3.47 5.00 3.50
Type of energy used - Electricity
Declared heating capacity and coecient of performance for part load at indoor temperature 20 °C and outdoor
temperature Tj
Outdoor temperature (Tj) = -7°C
Pdh kW 4.05 3.60 5.74 5.34
COPd - 3.26 2.08 3.09 2.18
Outdoor temperature (Tj) = +2°C
Pdh kW 2.48 2.26 3.47 3.11
COPd - 5.02 3.44 4.76 3.41
Outdoor temperature (Tj) = +7°C
Pdh kW 1.67 1.49 2.44 2.09
COPd - 6.70 4.33 6.65 4.36
Outdoor temperature (Tj) = +12°C
Pdh kW 1.14 1.02 1.48 1.23
COPd - 8.74 6.66 9.58 6.52
Outdoor temperature (Tj) = Bivalent
temperature (Tbiv )
Pdh kW 4.05 3.60 5.74 5.34
COPd - 3.26 2.08 3.09 2.18
Outdoor temperature (Tj) = Limit
operation temperature (TOL)
Pdh kW 4.56 3.59 6.14 5.81
COPd - 2.68 1.77 2.84 1.72
Bivalent temperature (Tbiv) heating/Average °C -7 -7 -7 -7
Limit operation temperature (TOL) heating/Average °C -10 -10 -10 -10
Degradation coecient (Cdh) - 0.9 0.9 0.9 0.9
Supplementary capacity (PSUP) kW 0.022 0.483 0.389 0.172
Annual energy consumption (QHE) kW·h 1830 2425 2680 3574