EasyManua.ls Logo

Hisense AHM-080HCDSAA - Refrigerant Cycle and Hydraulic Circuit of Hi-Therma Monobloc

Hisense AHM-080HCDSAA
489 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
54
Refrigerant cycle and hydraulic circuit
No. Part name No. Part name No. Part name No. Part name
1 Compressor 9 Low Pressure Switch (PSL) 17
Outdoor Unit Ambient
Thermistor (Ta)
25
Outlet Water Thermistor
(Tow)
2 Heat Exchanger 10 Accumulator 18
Compressor Discharge Gas
Thermistor (Td)
26 Water Pressure Sensor (Pw)
3
4-way Reversing Valve and
Coil
11 Plate Heat Exchanger 19
Heat Exchanger Liquid pipe
Thermistor (Te)
27 Shut-o󰀨 Valve with Filter
4 Strainer 12 Water Pump 20
Heat Exchanger Liquid pipe
Thermistor 2 (Te2)
28 Shut-o󰀨 Valve
5
Electronic Expansion Valve
and Coil
13 Expansion Vessel 21
Gas Refrigerant Pipe
Thermistor (Tg)
6 Refrigerant Check Joint 14
Pressure Adjustment Valve of
Expansion Vessel
22
Liquid Refrigerant Pipe
Thermistor (TL)
7 Refrigerant Check Joint 15 Air Purge Valve 23 Inlet Water Thermistor (Tiw)
8 High Pressure Switch (PSH) 16 Safety Valve 24
Outlet HP Water Thermistor
(TowHP)
7.3 Refrigerant cycle and hydraulic circuit of Hi-Therma Monobloc