13
General data
2.3.3 Cooling data- Hi-Therma Monobloc
Model
44(2.0 HP) 80(3.0 HP)
Outdoor unit AHZ-044HCDS1 AHZ-080HCDS1
Water outlet temperature 7ºC 18ºC 7ºC 18ºC
Product description
Outdoor side heat exchanger of air
conditioner/heat pump
Air
Indoor side heat exchanger of air
conditioner/heat pump
Water
Type Compressor driven vapour compression
Driver of compressor Electric motor
Capacity Control Variable
Indoor heat exchanger Variable Fixed Variable Fixed
Rated Cooling Capacity (PRATED,C) kW 4.40 5.60 6.5 7.0
Seasonal space cooling energy eciency (ηS,C) % 227 399 230 292
Seasonal energy eciency ratio cooling mode (SEER) - 5.75 10.06 5.83 7.38
Declared cooling capacity and coecient of performance for part load at indoor temperature 27(19) °C and outdoor
temperature Tj
Outdoor temperature (Tj) = 35°C
Pdc kW 4.40 5.60 6.50 7.00
EERd - 4.00 5.60 3.35 5.10
Outdoor temperature (Tj) = 30°C
Pdc kW 3.36 4.32 4.92 4.87
EERd - 5.43 8.40 5.00 5.55
Outdoor temperature (Tj) = 25°C
Pdc kW 2.02 2.74 3.18 3.28
EERd - 7.47 12.72 6.87 9.00
Outdoor temperature (Tj) = 20°C
Pdc kW 0.89 1.14 1.37 1.58
EERd - 5.30 12.61 7.35 9.93
Degradation coecient (Cdc) - 0.9 0.9 0.9 0.9