373
Synchronous Mode:
The communication format has a fixed eight-bit data length.
In receiving, it is possible to detect overrun errors (ORER).
An internal or external clock can be selected as the SCI clock source.
When an internal clock is selected, the SCI operates using the on-chip baud rate generator,
and outputs a serial clock signal to external devices.
When an external clock is selected, the SCI operates on the input serial clock. The on-chip
baud rate generator is not used.
Table 13.8 Serial Mode Register Settings and SCI Communication Formats
SMR Settings SCI Communication Format
Mode
Bit 7:
C/A
Bit 6:
CHR
Bit 5:
PE
Bit 2:
MP
Bit 3:
STOP
Data
Length
Parity
Bit
Multipro-
cessor Bit
Stop Bit
Length
Asynchronous 0 0 0 0 0 8-bit Absent Absent 1 bit
1 2 bits
1 0 Present 1 bit
1 2 bits
1 0 0 7-bit Absent 1 bit
1 2 bits
1 0 Present 1 bit
1 2 bits
0 * 1 0 8-bit Absent Present 1 bit
* 1 2 bits
1 * 0 7-bit 1 bit
* 1 2 bits
Synchronous 1 **** 8-bit Absent None
Note: Asterisks (*) in the table indicate don’t-care bits.
Asynchronous
(multiprocessor
format)