EasyManua.ls Logo

Hitachi SH7032 - A;D Converter Timing

Hitachi SH7032
690 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
513
SCK0, SCK1
t
scyc
t
RXS
t
TXD
t
RXH
TxD0, TxD1
(transmit data)
RxD0, RxD1
(receive data)
Figure 20.41 SCI I/O Timing (Synchronous Mode)
(9) A/D Converter Timing
Table 20.13 A/D Converter Timing
Case A: V
CC
= 3.0 to 5.5 V, AV
CC
= 3.0 to 5.5 V, AV
CC
= V
CC
±10%, AV
ref
= 3.0 V to AV
CC
,
V
SS
= AV
SS
= 0 V, φ = 12.5 MHz, Ta = –20 to +75°C
*
Case B: V
CC
= 5.0 V ±10%, AV
CC
= 5.0 V ±10%, AV
CC
= V
CC
±10%, AV
ref
= 4.5 V to AV
CC
,
V
SS
= AV
SS
= 0 V, φ = 20 MHz, Ta = –20 to +75°C
*
Note: * Regular-specification products; for wide-temperature-range products, Ta = –40 to +85°C
Cases A and B
Item Symbol Min typ Max Unit Figure
External trigger input pulse width t
TRGW
2.0 t
cyc
20.42
External trigger input start delay time t
TRGS
50 ns
A/D conversion
start delay time
CKS = 0 t
D
10 17 t
cyc
20.43
CKS = 1 6 9 t
cyc
Input sampling time CKS = 0 t
SPL
—64t
cyc
CKS = 1 32 t
cyc
A/D conversion
time
CKS = 0 t
CONV
259 266 t
cyc
CKS = 1 131 134 t
cyc

Table of Contents