EasyManua.ls Logo

Hitachi SH7032 - Refresh Control Register (RCR) BSC

Hitachi SH7032
690 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
614
A.2.46 Refresh Control Register (RCR) BSC
Start Address: H'5FFFFAC
Bus Width: 8/16/32 (read), 16 (write)
Register Overview:
Bit: 15 14 13 12 11 10 9 8
Bit name:
Initial value: 0 0 0 0 0 0 0 0
R/W:
Bit: 7 6 5 4 3 2 1 0
Bit name: RFSHE RMODE RLW1 RLW0
Initial value: 0 0 0 0 0 0 0 0
R/W: R/W R/W R/W R/W
Table A.47 RCR Bit Functions
Bit Bit Name Value Description
7 Refresh control (RFSHE) 0 No refresh control (Initial value)
(RTCNT can be used as an interval timer)
1 Refresh control
6 Refresh mode (RMODE) 0 CAS-before-RAS refresh performed (Initial value)
1 Self-refresh performed
5,4 Wait state insertion CBR 0 0 1-cycle wait state inserted (Initial value)
refresh 1,0 (RLW1, RLW0)
0 1 2-cycle wait state inserted
1 0 3-cycle wait state inserted
1 1 4-cycle wait state inserted