84
3.7.9 Procedure if an incomprehensible symptom occurs during use of the radar
If a symptom such as the distortion of screen display or the refusal of switch operation takes place
during use of the radar, perform the initialization procedure below.
Caution
●
●●
● When INITIALIZE is executed, ENGINEERS MENU is initialized. However, the
contents stored by BACKUP MEMORY are not initialized.
●
●●
● When the battery for backup wears down, the contents stored by
BACKUP MEMORY are initialized.
(a) Turn on the power while pressing the [MENU] key and [ACQ/ENT] key at the same time.
(b) The NO and YES menu is displayed after the menu below. Turn [JOG DIAL] to
select YES , and then press the [JOG DIAL] or [ACQ/ENT] key to determine the
selection.
INITIALIZE ALL SETTING
ARE YOU SURE?
NO
YES
INITIALIZE ALL