3.7.9 Procedure if an incomprehensible symptom occurs during use of the radar
If a symptom such as the distortion of screen display or the refusal of switch operation takes place
during use of the radar, perform the initialization procedure below.
Caution
When INITIALIZE is executed, ENGINEERS MENU is initialized. However, the
contents stored by BACKUP MEMORY are not initialized.
When the battery for backup wears down, the contents stored by
BACKUP MEMORY are initialized.
(a) Turn on the power while pressing the [MENU] key and [ACQ/ENT] key at the same time.
(b) The NO and YES menu is displayed after the menu below. Turn [JOG DIAL] to
select YES , and then press the [JOG DIAL] or [ACQ/ENT] key to determine the
selection.
INITIALIZE ALL SETTING
ARE YOU SURE?
NO
YES
INITIALIZE ALL