37
3.2.5 Operation termination and stop [STBY], [TX/PRF]
1. Canceling transmission [STBY]
Press the [STBY] key.
Transmission is canceled and the screen enters the standby state.
2. Turning off the power
Press the [STBY] key and [TX/PRF] key at the same time.
The radar enters the stopped state and all the functions stop.
Before starting maintenance work or the like, stop power supply by turning off the
power and disconnecting the power connector from the rectifier and the display.
Even if the power switch is turned off, there are live components in each unit. In
this status, maintenance or inspection work causes an electric shock, system
failure, or accident.