Page #293 background image
Sample Output
show interfaces diagnostics optics et-4/1/0 (CFP Transceiver)
user@switch> show interfaces diagnostics optics et-4/1/0
Physical interface: et-4/1/0
Module temperature : 38 degrees C / 101 degrees F
Module voltage : 3.2500 V
Module temperature high alarm : Off
Module temperature low alarm : Off
Module temperature high warning : Off
Module temperature low warning : Off
Module voltage high alarm : Off
Module voltage low alarm : Off
Module voltage high warning : Off
Module voltage low warning : Off
Module not ready alarm : Off
Module low power alarm : Off
Module initialization incomplete alarm : Off
Module fault alarm : Off
PLD Flash initialization fault alarm : Off
Power supply fault alarm : Off
Checksum fault alarm : Off
Tx laser disabled alarm : Off
Tx loss of signal functionality alarm : Off
Tx CDR loss of lock alarm : Off
Rx loss of signal alarm : Off
Rx CDR loss of lock alarm : Off
Module temperature high alarm threshold : 75 degrees C / 167 degrees F
Module temperature low alarm threshold : -5 degrees C / 23 degrees F
Module temperature high warning threshold : 70 degrees C / 158 degrees F
Module temperature low warning threshold : 0 degrees C / 32 degrees F
Module voltage high alarm threshold : 3.5000 V
Module voltage low alarm threshold : 3.0990 V
Module voltage high warning threshold : 3.4000 V
Module voltage low warning threshold : 3.2000 V
Laser bias current high alarm threshold : 250.000 mA
Laser bias current low alarm threshold : 37.500 mA
Laser bias current high warning threshold : 225.000 mA
Laser bias current low warning threshold : 50.000 mA
Laser output power high alarm threshold : 3.9800 mW / 6.00 dBm
Laser output power low alarm threshold : 0.4670 mW / -3.31 dBm
Laser output power high warning threshold : 3.5480 mW / 5.50 dBm
Laser output power low warning threshold : 0.5240 mW / -2.81 dBm
Laser rx power high alarm threshold : 3.5481 mW / 5.50 dBm
Laser rx power low alarm threshold : 0.0616 mW / -12.10 dBm
Laser rx power high warning threshold : 3.1622 mW / 5.00 dBm
Laser rx power low warning threshold : 0.0691 mW / -11.61 dBm
Laser temperature high alarm threshold : 67 degrees C / 153 degrees F
Laser temperature low alarm threshold : 35 degrees C / 95 degrees F
Laser temperature high warning threshold : 62 degrees C / 144 degrees F
Laser temperature low warning threshold : 40 degrees C / 104 degrees F
SOA bias current high alarm threshold : 0.000 mA
SOA bias current low alarm threshold : 0.000 mA
SOA bias current high warning threshold : 0.000 mA
SOA bias current low warning threshold : 0.000 mA
Lane 0
Laser bias current : 131.684 mA
Laser output power : 1.002 mW / 0.01 dBm
Laser temperature : 54 degrees C / 128 degrees F
Laser receiver power : 0.497 mW / -3.03 dBm
273Copyright © 2015, Juniper Networks, Inc.
Chapter 5: Operational Commands

Table of Contents

Other manuals for Juniper EX2200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX2200 and is the answer not in the manual?

Juniper EX2200 Specifications

General IconGeneral
Throughput77 Mpps
MAC address table8000 entries
Jumbo frames supportYes
Number of VLANs1024
Networking standards-
Switch typeManaged
SFP module slots quantity4
Installed SFP modules quantity0
Basic switching RJ-45 Ethernet ports quantity48
StackableNo
Product colorBlack
Power consumption (typical)100 W
Operating altitude0 - 3048 m
Non-operating altitude0 - 4877 m
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 45 °C
Storage relative humidity (H-H)0 - 95 %
Operating relative humidity (H-H)10 - 85 %
Weight and Dimensions IconWeight and Dimensions
Depth254 mm
Width441 mm
Height43 mm
Weight3600 g