State Online
Intake Temperature 47 degrees C / 116 degrees F
Exhaust Temperature 45 degrees C / 113 degrees F
Junction Temperature 57 degrees C / 134 degrees F
Power
1.0 V 1000 mV
1.5 V 1500 mV
1.2 V 1199 mV
3.3 V 3299 mV
0.9 V 900 mV
2.5 V 2499 mV
3.3 V bias 3333 mV
SIB 5 status:
State Online
Intake Temperature 57 degrees C / 134 degrees F
Exhaust Temperature 43 degrees C / 109 degrees F
Junction Temperature 71 degrees C / 159 degrees F
Power
1.0 V 1000 mV
1.5 V 1499 mV
1.2 V 1199 mV
3.3 V 3300 mV
0.9 V 900 mV
2.5 V 2500 mV
3.3 V bias 3307 mV
SIB 6 status:
State Online
Intake Temperature 57 degrees C / 134 degrees F
Exhaust Temperature 42 degrees C / 107 degrees F
Junction Temperature 66 degrees C / 150 degrees F
Power
1.0 V 1000 mV
1.5 V 1499 mV
1.2 V 1200 mV
3.3 V 3300 mV
0.9 V 899 mV
2.5 V 2500 mV
3.3 V bias 3311 mV
SIB 7 status:
State Online
Intake Temperature 58 degrees C / 136 degrees F
Exhaust Temperature 42 degrees C / 107 degrees F
Junction Temperature 67 degrees C / 152 degrees F
Power
1.0 V 999 mV
1.5 V 1500 mV
1.2 V 1199 mV
3.3 V 3299 mV
0.9 V 900 mV
2.5 V 2499 mV
3.3 V bias 3307 mV
SIB 8 status:
State Online
Intake Temperature 57 degrees C / 134 degrees F
Exhaust Temperature 43 degrees C / 109 degrees F
Junction Temperature 71 degrees C / 159 degrees F
Power
1.0 V 1000 mV
1.5 V 1500 mV
1.2 V 1199 mV
3.3 V 3299 mV
131Copyright © 2012, Juniper Networks, Inc.
Chapter 14: Troubleshooting Packet Transport Switch Hardware Components