user@host> show chassis environment pdu 0
PDU 0 status:
State Online
Hours Used 2161
Firmware Version (MCU1) 02.03
Firmware Version (MCU2) 02.01
Firmware Version (MCU3) 02.01
Firmware Version (MCU4) 02.01
PDU 0 PSM 0 status:
State Online
Temperature OK 35 degrees C / 95 degrees F
Fans OK
DC Input OK
DC Output OK
Hours Used 1379
Firmware Version 02.03
PDU 0 PSM 1 status:
State Online
Temperature OK 37 degrees C / 98 degrees F
Fans OK
DC Input OK
DC Output OK
Hours Used 1411
Firmware Version 02.03
PDU 0 PSM 2 status:
State Online
Temperature OK 37 degrees C / 98 degrees F
Fans OK
DC Input OK
DC Output OK
Hours Used 3135
Firmware Version 02.03
PDU 0 PSM 3 status:
State Online
Temperature OK 36 degrees C / 96 degrees F
Fans OK
DC Input OK
DC Output OK
Hours Used 1323
Firmware Version 02.03
4. Issue the show chassis power command to check the power usage in watts for all
PDUs and PSMs.
Chassis Power Input(V) Used(W)
Total Power 3810
PDU 0 3810
PSM 0
Input 1 54 331
PSM 1
Input 1 54 661
PSM 2
Input 1 54 1432
PSM 3
Input 1 54 1386
141Copyright © 2012, Juniper Networks, Inc.