Chapter 9 MDP-1241/1240/1260/1210
Navigation Data operation Operation manual
(5) Water temperature alarm
The water temperature alarm sounds (Beep!, Beep!, Beep!) if the water temperature is within the
set alarm range or alternatively outside the set range.
The alarm will activate if the alarm range and mode are set and ALARM is set to ON.
In alarm range: The alarm will sound if the water temperature is within the set alarm range.
Out alarm range: The alarm will sound if the water temperature is outside the set alarm
range.
NAV/PAGE1/ALARM
ARR AL
XTE
RETURN
SPEED
ANCHOR
TEMP NAV
PAGE1
NAV/PAGE1/ALARM/TEMP
L ARE
e.
MODE
OUT
Press the L AREA key to set the lower end of the alarm range.
(Using the rotary control)
Press the H AREA key to set the higher end of the alarm range.
(Using the rotary control)
9-8 0093161202-06