KRONE operation terminal Gamma
111
Pos: 26.30.26 /BA/I nfo-Center/Großpacke npresse/Hauptmenü s/Hauptmenü 1 Einstel lungen/Menü 1-6-3 „Blas zeit“ @ 18\mod_123798794 9350_78.doc @ 212065
8.11.6.3 Menu 1-6-3 „Blow time“
BPK40654
A
BPK40655
Fig. 64
You can adjust the blowing time on the knotter in this menu.
Calling the menu
Main menu 1-6 "Knotter blowing" appears.
You can select menu 1-6-3
with the rotary potentiometer. The symbol is shown in
reverse colours
Press the rotary potentiometer
The display shows menu 1-6-3 "Blow time".
The bar display and value (A) indicate the preselected cleaning time (blow time) in seconds.
The symbol
in the upper line indicates that the displayed value is saved.
• Press key
for softkey DEF: the factory setting value is accepted. The symbol in
the upper line may go out
Set the desired blow time with the rotary potentiometer. The symbol
in the top line
disappears
Press the rotary potentiometer. The set contrast value is saved and the symbol
appears in the upper line
You can use the key
to close the menu currently displayed
The display shows menu level 1-6 "Knotter blowing".
Pressing the key
repeatedly brings up the basic screen