11.8.2 Activating the bale ejector
Fig. 137
11.8.2.1 Medium design:
Activate the bale ejector (1) (in the medium design, the remaining bale ejector is activated
with the upper control lever (3) on the rear left of the machine
To do this:
If necessary open the shut-off valve (4) (position I)
Raise the safety sleeve (2) and move the control lever (3) to position (a) or (b)
Position (a): The bale ejector (1) is moved to the front.
Position (b): The bale ejector (1) is moved backwards.
Note
After ejection of the big bale it is absolutely essential to move the bale ejector to the forward
position. To do this, move the control lever (3) to position (a) as described above. Close the
shut-off valve (4) (position (II)) afterwards.
11.8.3 Comfort design:
In the case of the comfort design, this function can be switched from the control unit or on the
machine keys (see chapter Manual mode basic screen 2/2 “Automatic bale ejector”).