EasyManua.ls Logo

Krone Big Pack 890 - Setting the Locking (Frame); Setting the Lockings of the Needle Yoke

Krone Big Pack 890
352 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Settings
262
Pos: 38.116.7 /BA/Ei nstellungen/Großpac kenpresse/MutiBal e/Einstellung Ver riegelung (Rahmen) @ 24\ mod_1241498609820_78. doc @ 245279
12.14.5 Setting the locking (frame)
Fig. 202
Set the support tube (10) so that the distance between the locking (11) and the support
tube (10) is Z = 15-35 mm
Pos: 38.116.8 /BA/Ei nstellungen/Großpac kenpresse/MutiBal e/Einstellung Ver riegelungen der Nadelsc hwingen @ 24\mod_124150173 6055_78.doc @ 245306
12.14.6 Setting the lockings of the needle yoke
Fig. 203
In order to ensure a safe lock of the second needle yoke (13), the locking (11) (as shown in the
figure above) has to have a distance of U = 3 – 7 mm to the pin (12) of the needle yoke (14).