KRONE operation terminal Gamma
89
Pos: 26.8.16 /BA/I nfo-Center/Großpacken presse/Grundbild Handbetrieb/Einst ellen des Soll-Pressk lappendrucks @ 18\mod_12 37390053275_78.doc @ 210173
8.5.3 Setting the target bale channel flap pressure
Pos: 26.8.17 /BA/I nfo-Center/Großpacken presse/Grundbild Handbetrieb/W arnung zu hoher Druck @ 18\mod_1237389 601150_78.doc @ 210149
WARNING! – Pressure too high!
Effect: Damage to the machine
• If the pressure is set too high, the machine could be subjected to a mechanical overload
during baling that could result in destroying it To avoid this, the bale channel flap
pressure should be reduced to a non-critical value just before the overload. After a few
seconds, it is possible to return to the pressure set by the user.
• If overload occurs the target bale channel flap pressure must be reduced
Pos: 26.8.18 /BA/I nfo-Center/Großpacken presse/Grundbild Handbetrieb/Einst ellen des Soll-Pressk lappendrucks Einführ ung @ 18\mod_12373901255 10_78.doc @ 210197
The user will give the pressure in the manual mode. The pressure is built up immediately if the
P.T.O. shaft is running and the machine is stopped. The pressure display barely fluctuates in
the display.
Pos: 26.8.19 /BA/I nfo-Center/Großpacken presse/Grundbild Handbetrieb/Einst ellen des Soll-Pressk lappendrucks Bild @ 18\ mod_1237390387760_78.d oc @ 210245
Fig. 45
Pos: 26.8.20 /BA/I nfo-Center/Großpacken presse/Grundbild Handbetrieb/Einst ellen des Soll-Pressk lappendrucks Drehpo ti @ 18\mod_123739021499 4_78.doc @ 210221
Setting the target bale channel flap pressure
• Press the rotary potentiometer until the symbol
is in front of the target bale channel
flap pressure value (A)
• Turn the rotary potentiometer to set the desired target bale channel flap pressure
• Press the rotary potentiometer until the symbol
is in parking position (B)
Pos: 26.8.21 /BA/-----Seitenumbruch------ @ 0\mod_1196175311226_0.doc @ 4165