Maintenance – lubrication
316
Pos: 42.58 /Überschri ften/Überschri ften 3/A-E/Einstell ung der Sensoren @ 0\mod_1199962 173428_78.doc @ 37635
15.9.1 Adjusting the Sensors
Pos: 42.59 /BA/W artung/Sensoren/Namursen sor d = 08 mm @ 24\mod_124177031236 9_78.doc @ 248607
15.9.1.1 Namur sensor d = 8 mm
a
BP-VFS-088-1
2
1
3
Figure 235:
The dimension between the encoder (2) and the sensor (1) must be "a" = 0,5 mm .
Setting
• Loosen the nuts on either side of the sensor.
• Turn the nuts until dimension "a" = 0,5 mm is reached.
• Tighten the nuts again.
Pos: 42.60 /BA/W artung/Sensoren/Namursen sor d = 12 mm @ 0\mod_1199962247038 _78.doc @ 37654
15.9.1.2 Namur sensor d = 12 mm
a
BP-VFS-088-1
2
1
3
Figure 236
The dimension between the encoder (2) and the sensor (1) must be "a" = 2 mm .
Setting
• Loosen the nuts on either side of the sensor.
• Turn the nuts until dimension "a" = 2 mm is reached.
• Tighten the nuts again.