9.15 Alarm messages
Pos: 28.148.1 /BA/I nfo-Center/Großpacke npresse/Hauptmenü s/Alarmmeldungen/1) Alarmmeldungen Tabe lle allgemein A01 - A15 @ 19\mod _1238493861603_78. doc @ 219958
No. Image Description Possible cause Remedy
A01
Fuse 2 defective
Short circuit at the
outputs
Replace the fuse and then test all
actuators in the actuator test to
determine whether an actuator has
a short circuit.
A02
Fuse 3 defective (self-
repairing)
Short circuit in electrical
power supply for
sensors.
Check wiring to MultiBale
potentiometer, star wheel,
pressure sensor and force
measurement amplifier.
A03
CAN connection
between terminal and
job computer
interrupted
CAN wiring defective Check the CAN wiring
A04
EEPROM error Job computer defective Replace the job computer
A05
CAN connection
broken between job
computer and KRONE
I/O computer
CAN wiring defective
KRONE I/O computer
inactive
Check the CAN wiring
Check the cables
Replace KRONE I/O computer
A11
Wrong display
Medium display is
connected to comfort
machine.
Connect comfort display.
A14
Undervoltage
- Tractor battery
defective
- Tractor dynamo too
weak
- 12-V power supply too
weak on the tractor side
or not correctly
connected with the
battery
Connect the KRONE connection
cable to the tractor battery
A15
Overvoltage
Tractor dynamo
defective
Check dynamo