Malfunctions - Causes and Remedies
333
Pos: 46.30 /BA/Störunge n - Ursachen und Behebung/ Großpackenpressen/S törungen-Ursac hen-Behebung Doppelkn oter T6 @ 25\mod_1242036861 416_78.doc @ 249592
No
.
Malfunction Cause and/or remedy
7 Second knot: (Starting knot) Knot is present
only on the upper twine strand (no knot on
the lower twine
strand).
7.1
Cause:
The lower twine tension springs are not working
properly.
Remedy:
Ensure free room for the lower twine tension springs (5).
Tighten the twine brake (1) by:
• tightening the spring (2) by about one to two turns
of the winged nut (3)
7.2
Cause:
Not enough needle overrun in the upper dead
point.
Remedy:
Check the needle setting (refer to chapter settings
"Needle setting").
7.3
Cause:
The twine bar is not working precisely or is
adjusted incorrectly.
Remedy:
Check the twine bar settings (refer to chapter "Setting
the twine bar (double knotter)").
Pos: 46.31 /BA/-----Seitenumbruch------ @ 0\mod_1196175311226_ 0.doc @ 4165