IPECS Release 5
Feature Description & Operation 5.0
2-53
2.20 CO/IP CALL TIME RESTRICTION
Description
The system can be programmed to limit the length of outgoing calls by specified stations. When a
specified station places an outgoing call, the system initiates the Call Restrict timer and, 15 seconds
prior to expiration, a warning tone is delivered. At expiration, the system terminates the call returning
the external CO/IP line to idle.
Operation
System
Operation of this feature is automatic when assigned
Conditions
1. Once activated, the Call Warning Tone timer continues timing while the call is connected to the
system even if the call is transferred or picked up at another station.
Programming
STATION 1. CO/IP Call Time Restriction (PGM 112-Btn 3)
2. Cut Off Timer (PGM 123-Btn 2)
Related Features
CO/IP Call Warning Tone Timer
Hardware
2.21 CO/IP CALL WARNING TONE TIMER
Description
Stations can receive a tone indicating the elapsed time of a CO/IP call has reached the Warning
Tone time. The station hears the tone after the CO Warning Tone Timer has elapsed.
Operation
System
Operation of this feature is automatic when assigned
Conditions
1. Warning tone is received 15 seconds prior to expiration of the timer and is repeated at intervals
equal to the Warning Tone Timer.
Programming
STATION 1. CO Call Time Tone (PGM 112-Btn 1)
S
YSTEM 1. Elapsed Call Tone Timer (PGM 180-Btn 19)