Probing
This document only covers Z height probing though there are many more probing routines built into MASSO.
Z height probing can be done with either inside or outside probing screens.
Part probing instructions
For probing your Z height enter the thickness of your touch off plate into Z Offset.
If using a probing tool, Z offset is zero and you enter a value into the Probe diameter.
Set a Probing feed rate and enter click save settings.
Probe by clicking the center square.
Once probing is complete MASSO will automatically update the DRO with the new value.
Hint: If you want to reference your cutter to the surface of the spoilboard you can enter the
negative of the nominal material thickness into Set Z and it will work everything out for you. eg for
18mm material enter -18 onto Set Z.