25 - 4
NOTE
• When ECG Lead Set is set to 3-Lead, ECG report cannot be printed.
25.6.2 Setting Realtime Reports
To set tabular realtime reports, follow this procedure:
1. Select the Main Menu quick key → from the Report column select Normal Report.
1. Select Realtime Report.
2. Set the desired options. The following table only lists some of the options.
25.6.3 Setting Tabular Trends Reports
To set tabular trends reports, follow this procedure:
1. Select the Main Menu quick key → from the Report column select Report Setup.
2. Select Tabular Trends Report.
3. Set the desired options. The following table only list some of the options.
Rhythm Lead 1
Rhythm Lead 2
Rhythm Lead 3
Select the lead that will
be used as Rhythm
Lead 1, 2, or 3.
I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
Note: This setting is only relevant when
6×2+1,3×4+1, or 3×4+3 is selected for 12-Lead
Format
.
Format Sequence Select the recording
method of ECG report
generated by auto
measurement
Sequential: 12-lead ECG data are recorded sequentially and
displayed in 3 lines and 4 columns with 2.5 seconds of ECG data for
each column.
Simultaneous: Record simultaneous 12-lead ECG data.
Menu item Function Description
Menu item Function Description
Select Waveform Select the desired
waveform to print
Current Waveforms: prints the realtime report for current
waveforms.
Selected Waveforms: prints the realtime report for the
selected waveforms.
Menu Item Function Description
Period Select the period during which a
tabular trends report will be printed.
Auto: one page of a tabular trends according to the selected
interval.
Interval Select the resolution of the tabular
trends printed on a report.
NIBP, EWS, GCS, C.O.: at an interval of acquiring the values
of selected parameter.
Auto: using the Interval setting of the Tabular Trends
review page.
Report Format Select the printing principle.
Parameter Oriented: print one page of report by
parameters when
Interval is set to Auto.
Time Oriented: print one page of report by time when
Interval is set to Auto.