4 - 6
4.5.4 Setting OxyCRG Parameters
Select parameter trends or compressed waveform to set parameters and the compressed waveform you want to
display. The selected parameters will be used for ABD event calculation.
4.5.5 Setting the Threshold of ABD Events
Select any parameter trend or the compressed waveform to perform the following setup:
â–  Set the threshold of ABD events.
â–  Set Event Storage Format:
â—† 1 min+3 min: stores data one minute before and three minutes after the event.
â—† 3 min+1 min: stores data three minutes before and one minute after the event.
â—† 2 min+2 min: stores data two minutes before and two minutes after the event.
The stored data includes the trends of the OxyCRG parameters, compressed waveform, alarm thresholds, NIBP,
and Temp measurements.
4.5.6 Editing ABD Events
To edit ABD events, follow this procedure:
1. Select the Mark button to enter the Mark dialog box.
2. Drag the event list upwards and downwards to select the desired event.
3. Select the patient’s status when the event happens.
4. Select Save.
4.6 The Targeted Goal Screen
If you are concerned with specific parameters and their trends, you can use the Targeted Goal screen. The
Targeted Goal screen focuses on the target parameter and displays parameter measurements in big numerics.
You can easily identify whether parameter target is reached via a dashboard and review the statistics of the
target parameter by sections.
The Targeted Goal screen displays parameter measurements and waveforms of ECG, SpO
2
, IBP, PI, PR, CO
2
, Resp,
NIBP, and Temp. You can define the target parameter and secondary parameters. The measurements of these
parameters displays in big numerics.
4.6.1 Entering the Targeted Goal Screen
To enter the Targeted Goal screen, choose any of the following ways:
■ Select the Screen Setup quick key → select the Choose Screen tab → select Targeted Goal.
■ Select the Main Menu quick key → from the Display column select Choose Screen → select Targeted
Goal.
â–  If the Patient Category is set to Neo, swipe left or right on the touchscreen with two fingers to switch to
the Targeted Goal screen.