7 - 5
7.5.2.1 About Alarm Watch Tile
The main screen can display up to three alarm watch tiles, namely A-W1 and A-W2. Each tile can accommodate
up to six beds.
The following figure shows the alarm watch tiles.
The alarm watch tile is similar to alarm watch area in the Remote View. For more information, see 7.5.1.2About
the Remote View.
7.5.2.2 Displaying the Alarm Watch Tile on the Main Screen
To configure the alarm watch tile to be displayed on the monitor’s main screen, follow this procedure:
1. Select the Main Menu quick key → from the Display column select Choose Screen to enter the Screen
Setup menu.
2. Select the Tile Layout tab.
3. Select the numeric area where you want to display the alarm watch tile, and then in the drop-down list,
select Alarm Watch → A-W1 or A-W2.
7.5.3 Auto Displaying the New Alarm Bed
The monitor provides the function of automatically displaying the remote alarm bed. If this function is enabled,
when a remote bed issues an alarm, the monitor automatically displays the monitoring information from this
remote bed.
If multiple remote beds issue alarms, the monitor cyclically displays the alarm beds as per the preset interval and
in the order of alarm time.
The auto displaying alarm bed function is disabled by default. To enable this function, follow this procedure:
1. From the Remote View screen, select
to enter the Remote View setup menu.
2. Switch on Rollup Alarm Beds.
3. Set Rollup Interval:
â—† Off: do not cyclically display the remote alarm beds. Once a new alarm is issued, the monitor
automatically switches to the new alarm bed.
â—† 10 sec, 20 sec, or 30 sec: If multiple remote beds issue alarms, the monitor cyclically displays the
alarm beds as per the preset interval and alarm priority in the order of alarm time.
4. Set Alarm Priority:
(1)
(5)
(4)
(3)
(2)
(1)
(3)
(1)
Alarm watch tile label
(2)
Disconnection icon: when the remote device is disconnected, this icon displays at the tile, and the tile
background color is red.
(3)
Select bed icon: select it to enter the Select Bed window.
(4)
More than one bed tile: when more than one bed is assigned to a tile, the tile displays the alarm status,
connection status, etc.
(5)
One bed tile: when only one bed is assigned to a tile, the tile displays the parameter value and alarm
message from this bed, etc.