Corner correction @admin
LC 1
LC 2
LC 3
LC 4
6.317 t
4.854 t
2.421 t
5.102 t
You are free to choose any desired order.
Corner correction @admin
LC 1
LC 2
LC 3
LC 4
4.321 t
3.287 t
4.133 t
6.960 t
When corner correction is completed, it is marked with [Correction ok].
WP-D
Max 200t d= 0.02t
Min 0.4t
Calibration @admin
Calibration weight
Corner correction
11.000 t
correction ok
Vessel Save
4. Position (here: LC 1) is highlighted.
5. Conrm position.
6. Remove the calibration weight.
7. Repeat steps 1 to 6 for the remaining load cells.
8. Once all load cells have been loaded one time, press the [Calculate] soft key to
perform corner correction.
The total weight remains unchanged. Only the eect of the individual load cells is
corrected.
9. Press the [Save] soft key to save the corner correction.
Process Controller Maxxis 5 PR 5900 4 System setup
Minebea Intec EN-212