4.7.8.4 Units
In this menu item, the display units and display accuracy of the weighbridge load cell
Pendeo
®
Process are congured.
Descriptions and settings can be found in the [Internal weighing point] menu; see
Chapter 4.7.1.3.
Accessible via MENU - [Operating] - [System setup] - [Weighing points] - [Weighing
point x] - [Units] .
WP-D
Max -------?? d= -------??
scale not ready
Weighing points @admin
Weighing point A
Weighing point B
Weighing point C
Weighing point D
Internal weighing point
Internal weighing point
xBPI scale
Pendeo Process
Parameters Calib Units
Descriptions and settings can be found in the [Internal weighing point] menu; see
Chapter 4.7.1.3.
4.7.9 PR-Net weighing point
In this menu item (under Weighing points), the weighing electronics of a PR-Net
weighing point are assigned to a logical weighing point and congured.
- [Parameters] (weighing electronics), see Chapter 4.7.9.1.
PR 5900 can communicate with the following indicators via the network protocol:
- PR 5220
- PR 5230
- PR 5410
The determination and transmission of weight depends on the devices. Weight values up
to seven digits plus preceding +/- sign can be displayed. Before the weighing electronics
can be assigned to the logical weighing point, the scale (e.g.: PR 5230 + load cells) must
be calibrated and congured accordingly. The calibration cannot be modied via the
network protocol.
Accessible via MENU - [Operating] - [System setup] - [Weighing points] - [Weighing
point x] - [Weighing point] - [PR‑Net weighing point] .
In this case: Select [Weighing point D] with [Pendeo Process] and press the [Units]
soft key.
4 System setup Process Controller Maxxis 5 PR 5900
EN-213 Minebea Intec